THE STANDARD OEM MODULE MAY BE CONFIGURED WITH:
- Up to five new MINI Degassing Chamber design
- ZHCR® Control P.C. Board
- ZHCR® Vacuum Pump

- Flow-through vacuum degassing chamber with a single amorphous perflourinated copolymer (Teflon® AF) degassing membrane.
- Continuously vented vacuum system
- ZHCR® vacuum pump, a two-stage, series, stepper motor driven, vacuum pump with a unitary PTFE diaphragm
- ”System condition responsive”, ZHCR® electronic control which continuously monitors the system for faults, and operates the vacuum pump in two modes: high RPM to evacuate the vacuum chamber(s), and low RPM to sustain a constant vacuum level
- Fifty (50) times the degassing efficiency over PTFE designs, reducing internal volumes and overall package dimensions proportionately
- Very clean detector baselines due to absolutley zero vacuum hysteresis of the ZHCR® technology – the vacuum pump runs virtually silently and continuously at low RPM- Easy to prime (low flow resistance), ultra-low internal volume, zero dead volume, metal-free degassing membrane
- ”Ready to run” degassing system equilibration times of three minutes or less
- ZHCR® vacuum pump life expectancies > 220 million cycles (typically 5 years)
- Continuously vented vacuum system
- ZHCR® vacuum pump, a two-stage, series, stepper motor driven, vacuum pump with a unitary PTFE diaphragm
- ”System condition responsive”, ZHCR® electronic control which continuously monitors the system for faults, and operates the vacuum pump in two modes: high RPM to evacuate the vacuum chamber(s), and low RPM to sustain a constant vacuum level
- Fifty (50) times the degassing efficiency over PTFE designs, reducing internal volumes and overall package dimensions proportionately
- Very clean detector baselines due to absolutley zero vacuum hysteresis of the ZHCR® technology – the vacuum pump runs virtually silently and continuously at low RPM- Easy to prime (low flow resistance), ultra-low internal volume, zero dead volume, metal-free degassing membrane
- ”Ready to run” degassing system equilibration times of three minutes or less
- ZHCR® vacuum pump life expectancies > 220 million cycles (typically 5 years)
ZHCR® control with built-in test diagnostics, including:
- Microcontroller self-test vacuum sensor validation on power-up
- Continuous vacuum system monitoring to ensure optimum operational conditions are maintained
- Vacuum system fault detection and shutdown function indicators
- Microcontroller self-test vacuum sensor validation on power-up
- Continuous vacuum system monitoring to ensure optimum operational conditions are maintained
- Vacuum system fault detection and shutdown function indicators
Read more:
[issuu autoFlip=true width=420 height=297 embedBackground=%23ffffff shareMenuEnabled=false backgroundColor=%23222222 documentId=110308091619-391459f613334f46904f6d8ac2f5de45 name=idexhs_systec_oem_mini_degas_module_a4e username=biotech-sweden tag=module unit=px id=7d7d0f2d-4428-34ef-abb1-025279fee9f5 v=2]